-40%

500x Mixed Cellulose Ester (MCE) Membrane Filter + 50mL Conical Centrifuge Tubes

$ 22.8

Availability: 14 in stock
  • Fitler Sterile: Yes
  • Filter Packing: Individual
  • Filters Pore Size(μm): 0.45
  • Filter Wettability: Hydrophilic
  • Package Included: 25x(Test Tubes Only)
  • Condition: New
  • Brand: Membrane Solutions
  • Filter Diameter(mm): 47
  • Model: MFMCE047045GWS
  • MPN: LBGMMC001

    Description

    500x Mixed Cellulose Ester (MCE) Membrane Filter + 50mL Conical Centrifuge Tubes
    Membrane Solutions Gridded Membrane Filter
    MCE Gridded Membrane Filter are composed of cellulose acetate and cellulose nitrate. It is one of the most widely used membranes in analytical and research applications. MCE gridded membranes are designed for the recovery and retention of bacteria in microbiological analysis applications. White gridded disks are designed for the recovery and retention of E. Coli bacteria in water/wastewater analysis as well as other microbiological tests. The filters are certified to meet specifications listed in APHA Standard Methods.
    Features:
    1) Application:
    Mixed Cellulose Ester (MCE) membrane Filter is composed of cellulose acetate and cellulose nitrate, which is higly biologically inert with good thermal stability and widely used in Microboilogical analysis of water, wastewater, cosmetic, pharmaceuticals and beverages.
    2) High Quality Membrane:
    Sterile gridded membrane filter is without support layer naturally hydrophilic membrane, ideal for Colony Counting and Sterility Testing, and our MCE membrane with ISO 9001 certificated and meet ISO 7704 requirements.
    3) 3.1mm Intervals Grid Line:
    Gridded filters have clearly defined grid lines spaced at 3.1mm intervals. Contrasting grid lines facilitate counting colonies on the filter surface and are tested to assure freedom from grid line inhibition.
    4) High Porosity:
    Microbail membrane filter have high porosity allows gases and liquids to provide high filtration rates in every area. High porosity also provides a large surface area for adsorption and binding. High degree of internal surface area for greater adsorption of product.
    5) Sterile Individual Package:
    Membrane filter disc filters sterilized by 25 kGrey gamma radiation, sterile-sealed without protective paper, placed on a band in individual packages. This special setting ensures each membrane filter will stay perfectly flat when they are dispensed.
    6) High Purity:
    Triton-free
    Technical Specification:
    Part No.
    MFMCE047045GWS
    Material
    MCE (Mixed Cellulose Ester)
    Pore Size(μm)
    0.45
    Diameter(mm)
    47
    Gride Width(mm)
    3.1
    Thickness(μm)
    90-110
    Chemical Compatibility
    PH 3-8
    Max. Temperature (

    )
    90
    Wettability
    Hydrophilic
    Sterile
    Gamma irradiated, 25 kGrey
    Membrane|Grid Color
    White|Black
    Packing
    Individual
    Surface
    Gridded
    Microbiological Recovery Rate
    ≥90%
    Bacterial Retention Rate
    ≥99.99%
    Membrane Solutions 50ml Centrifuge Tubes
    MS®
    Centrifuge Tubes are made of high-clarity polypropylene with feature black printed graduations and a large white marking spot. Smooth, flat surface polyethylene caps for conical bottom tubes and plug seal caps for self-standing tubes are included.
    Specifications:
    Part No.
    LBCT500S
    Volume(ml):
    50ml
    Material:
    Polypropylene
    Feature:
    Conical(graduation)
    Packaging:
    25pcs/pk
    Sterile:
    Yes
    Features:
    High purity PP Material
    Easy-to-read black graduations are accurate to ±2%, 2.5mL increments (50mL), with a large white marking spot
    Smooth, flat inner surface,No residual solution
    Longer length screw caps with sealing ring
    Max.RCF: 9,400 for conical bottom tubes
    Autoclavable at 121℃ and freezable to -80℃
    Gamma radiation sterilized, non- pyrogenic, DN/RNase free
    Leak-proof
    Notice:
    1. Please check if the packaging is intact before use to ensure the sterilization environment.
    2. Please check the matching degree between the cover and the pipe body, and whether the pipe body has cracks or white spots on the bottom to prevent leakage of liquid leakage caused by mismatch during use.
    3. When centrifuging, the liquid sample in the centrifuge tube is usually 2/3 of the volume of the centrifuge tube and tightly closed to prevent liquid spillage.
    4. Centrifuge tubes must be placed in pairs and must be strictly balanced.
    Package Included:
    Test Tubes Only
    25x Test Tubes
    100x Test Tubes
    500x Test Tubes
    MCE Filters Only
    100x MCE Filters
    500x MCE Filters
    Test Tubes+MCE Filters
    100x Test Tubes+100x MCE Filters
    500x Test Tubes+500xMCE Filters
    Membrane Solutions
    , professional manufacturers and suppliers of laboratory items:
    More Choice !!!
    250uL Vials Inserts
    MCE Membrane Filters
    15mL/50mL Centrifuge Tubes
    2mL Clear Vials & Caps
    2mL Amber Vials & Caps
    M-Blue Nitrile Gloves
    Sterile PES Syringe Filters
    Buy it Now
    Buy it Now
    Buy it Now
    Buy it Now
    Buy it Now
    Buy it Now
    Buy it Now
    On Jun 24, 2024 at 23:29:11 PDT, seller added the following information: